Articles

Comparison of Multiplex PCR-ELISA and conventional Multiplex PCR for detection of HIV-1/HCV co-infection

Abstract

Background and Objectives: PCR is a sensitive assay and could be used as an accurate diagnostic method for detecting various types of microorganisms' genome in low concentration in biological specimens. The demand for sensitive, rapid, safe and easy detection of PCR products has led researchers to a combination of this method with ELISA.
Materials and Methods: Conserved sequences were selected for design of primers. Samples were tested by ELISA (for detection of specific HIV and HCV proteins) and real- time PCR for detection of specific nucleic acid and viral genome respectively. Viral genome was extracted and reverse transcription was performed with M-Mulv and the cDNA kept at -80º C. The PCR products were labeled by DIG-dUTP. Diluted PCR products were analyzed with both electrophoresis and ELISA methods.
Results: Thirty-five samples were tested with the PCR-ELISA method. False positive or negative reactions were not observed. ELISA results of diluted products were compared with results obtained by electrophoresis. In gel electrophoresis, dilution of 1/10 was positive, but in ELISA, optical density of 1/100 dilution was much more than the cut-off value.
Conclusion: Detection limits for gel electrophoresis as well as ELISA have been evaluated. It was shown that the PCR-ELISA method is ten times more sensitive than conventional PCR.

Defoort JP, Martin M, Casano B, Prato S, Camilla C, Fert V. Simultaneous detection of multiplex-amplified human immunodeficiency virus type 1 RNA, hepatitis C virus RNA, and hepatitis B virus DNA using a flow cytometer microsphere-based hybridization assay. J Clin Microbiol 2000; 38: 1066-1071.

Candotti D, Fletcher-brown F, Pierre allain J, Leei H.Simultaneous visual detection of multiple viral amplicons by dipstick assay magda anastassova dineva. J Clin Microbiol 2005; 43: 4015-4021.

Guatelli JC, Gingeras TR, Richman DD. Nucleic acid amplification in vitro: detection of sequences with low copy numbers and application to diagnosis of human immunodeficiency virus type 1 infection. J Clin Microbiol 1989; 2: 217-226.

Stoeckl E, Barrett N, Heinz FX, Banekovich M, Stingl G, Guggenberger K, et al. Efficiency of the polymerase chain reaction for the detection of human immunodefi- ciency virus type (HIV-1) DNA in the lymphocytes of infected persons: comparison to antigen-enzyme- linked immunosorbent assay and virus isolation. J Med Virol 1989; 29: 249-255.

Vyas GN, Yang G, Murphy E. Transfusion related transmissible diseases: Detection by polymerase chain reaction-amplified genes of the microbial agents. Transfus Med 1994; 8: 253-266.

Hart C, Schochetman G, Spira T, Lifson A, Moore J, Galphin J, et al. Direct detection of HIV RNA expression in seropositive subjects. Lancet 1988; 2: 596-599.

Mahony JB. Multiplex polymerase chain reaction for the diagnosis of sexually transmitted diseases. Clin Lab Med 1996; 16 :61-71.

Tenorio A, Echeverria JE, Echeverria ICJM, Tabares E.Detection and typing of human herpes viruses by multiplex polymerase chain reaction. J Virol Methods 1993; 44:261-269.

Schoske R, Vallone PM, Ruitberg CM, Butler JM.Multiplex PCR design strategy used for the simultaneous amplification of 10 Y chromosome short tandem repeat (STR) loci. Anal Bioanal Chem 2003; 75: 333-343.

Rachlin J, Ding C, Cantor C, Kasif S. MuPlex: multi- objective multiplex PCR assay design. Nucleic Acids Res 2005; 33. w544-w547.

Kox LFF, Noordhoek GT, Kunakorn M, Mulder S, Sterrenburg M, Kolk AHJ. Microwell Hybridization Assay for Detection of PCR Products from Mycobac- terium tuberculosis Complex and the Recombinant Mycobacterium smegmatis Strain 1008 Used as an Internal Control. J Clin Microbiol 1996; 34: 2117-2120.

Meng Q, Wong C, Rangachari A, Tamatsukuri S, Sasaki M, Fiss E, et al. Automated multiplex assay system for simultaneous detection of hepatitis B virus DNA, hepatitis C virus RNA, and human immunodefi- ciency virus type 1 RNA. J Clin Microbiol 2001; 39:2937-2945.

Forcic D, Mazuran R, Lupret L, Hecimovic A, Zgorelec R. Optimal pool size and window period. Trans Apher Sci 2001; 25: 153-155.

Ansaldi F, Bruzzone BM, Durando P, Lee S, De luigi C, Crovari P. Novel approach to reduce the hepatitis C virus (HCV) window period: clinical evaluation of a new enzyme-linked immunosorbent assay for HCV core antigen. J Clin Microbiol 2001; 39: 3110-3114.

Müller breitkreutz K, Baylis S, Allain J, sanguinis V.Nucleic acid amplification tests for the detection of blood-borne viruses. Vox Sanguinis 1999; 76: 194-200.

Chyang T. Blood screening for HBV DNA. J Clin Virol 2006; 36: 30-32.

Adami V, Falasca E, Dorotea L, Malangone1 W, Astori G, Marini L, et al. Qualitative multiplex RT-PCR for simultaneous detection of hepatitis C virus and human immunodeficiency virus in plasma samples. Clin Microbiol Infect 2004; 10: 1075-1080.

Candotti D, Temple J, Owusuofori S, Allain J. Multiplex real-time quantitative RT-PCR assay for hepatitis B virus, hepatitis C virus, and human immunodeficiency virus type 1. J Virol Methods 2004; 118: 39-47.

Wang N, Gao X, Han J-X. Simultaneous detection of HBV and HCV by multiplex PCR normalization. World J Gastroenterol 2004; 10: 2439-2443.

Gibellini D, Gardini F, Vitone F, Schiavone P, Furlini G, Carla re M. Simultaneous detection of HCV and HIV-1 by sybr green real time multiplex RT-PCR technique in plasma samples. Mol Cell probes 2006; 10: 223-229.

Wellinghausen N, Wirths B, Essig E, Wassill L. Evalu- ation of the hyplex bloodscreen multiplex PCR-en- zyme-linked immunosorbent assay system for direct identification of gram-positive cocci and gram-negative bacilli From positive blood cultures. J Clin Microbiol 2004; 42: 3147-3152.

Motta do canto L, Vallone PM, pannuti C, Cedenho A, Srougi M, Spaine D, et al. Detection of HIV and HCV RNA in semen from brazilian coinfected men using mul- tiplex PCR before and after semen washing. Rev Inst Med Trop S Paulo 2006; 48: 201-206.

Puppe A, Weigl jai, Aronc G, Gröndahl B, Schmitt B, Niesters HGM, et al. Evaluationof a multiplex reverse transcriptase pcr elisa for the detection of nine respiratory tract pathogens. J Clin Virol 2004; 30: 165-174.

Elnifro L, Ahmed M, Ashshi L, Robert J, Cooper L, et al. Multiplex PCR: optimization and application in diagnostic virology. J Clinic microbiol 2000; 13: 559-570.

Lahijani S, Taylor L. HIV-HCV Co infection Update.November 2006; 1-6. www.hcvadvocate.org.

Musiani M, Venturoli S, Gallinella G, Zerbini M.Qualitative PCR-ELISA protocol for the detection and typing of viral genomes. Nat Protoc 2007; 2: 2502-2510.

Khanlari Z, Ravanshad M, Rasouli M, Ziyaeyan M. A novel sensitive multiplex RT-PCR ELISA method for detection of HIV-1/HCV co-infection. Modares J Med Sci 2008; 11: 57-63.

Hecht FM, Busch MP, Rawal B, Webb M, Rosenberg E, Swanson M, et al. Use of laboratory tests and clinical symptoms for identification of primary HIV infection. AIDS 2002; 16: 1119-1129.

Linnen J, Broulik A, Broulik A, Umali D, Kolk J, Dockter S, et al. Analytical sensitivity of the TMA- based Procleix Ultrio assay and effect of assay sensitivity on closing the HBV detection window. Trans Apher Sci 2002; 42: 8.

Wang E, Paessler S, Aguilar P, Carrara A, Greene I, Weaver S. Reverse Transcription -PCR-Enzyme Linked Immunosorbent Assay for Rapid Detection and Differentiation of Alphavirus Infections. J Clinic Microbiol 2006; 44: 4000-4008.

Files
IssueVol 1 No 4 (2009) QRcode
SectionArticles
Keywords
Multiplex PCR- ELISA HIV HCV

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
How to Cite
1.
Ravanshad M, Khanlari Z, Rasouli M, Ziyaeyan M, Falahi S. Comparison of Multiplex PCR-ELISA and conventional Multiplex PCR for detection of HIV-1/HCV co-infection. Iran J Microbiol. 1;1(4):3-8.